Browning v belt tension checker9/16/2023 ![]() This number represents the force (in pounds) required to give the needed deflection.Ħ. The small O-ring now indicates a number other than zero on the plunger’s force scale. Place the large end of the gauge at the center of the belt span then depress the gauge plunger until the large O-ring is even with the top of the next belt or even with a straightedge placed across the fan and motor sheaves.ĥ. Set the small O-ring at zero on the force scale of the gauge plunger.Ĥ. Set the large O-ring on the belt tension gauge at the deflection value determined in Step 1b.ģ. Divide the distance measured in Step 1a by 64 the resulting value represents the amount of beltĭeflection that corresponds to the proper belt tension.Ģ. Measure the center-to-center shaft distance (in inches) between the fan and motor sheaves.ī. ![]() To determine the appropriate belt deflection Ī. ![]() Once the new belts are installed, using a Browning or Gates tension gauge (or equivalent) illustrated inįigure 33 adjust the belt tension as follows ġ. Loosen the belts using the belt tension adjustment bolts on the motor mounting base. When removing or installing the new belts, do not stretch them over the sheaves. Units with dual belts require a matched set of belts to ensure equal belt length. Replacement is necessary if the belts appear frayed or worn. The fan belts must be inspected periodically to assure proper unit operation. ![]()